In order to quickly and accurately extract the timing information of full-custom standard cells
a method of extracting timing information of standard cells based on Hsim is proposed. After the design of the full-custom standard cell layout
it is necessary to simulate the standard cell in different load
input transition time and the fastest
slowest and typical cases
to obtain the accurate timing information. Taking the standard cell of D flip-flop as an example
this paper introduces the process of quickly extracting the timing information of standard cells by using the measurement script based on Hsim. The results show that the method achieves fast and accurate extraction of the timing information of standard cells
and the measurement results provide guidance for the use of standard cells.