Research on Middle Frequency Voltage Test Technique Used in Turn-to-turn Insulation Test for Pole Coils of Large Electrical Machines
|更新时间:2026-07-10
|
Research on Middle Frequency Voltage Test Technique Used in Turn-to-turn Insulation Test for Pole Coils of Large Electrical Machines
Vol. 14, Issue 2, Pages: 50-54(2009)
作者机构:
哈尔滨理工大学电气与电子工程学院
作者简介:
基金信息:
DOI:
CLC:TM303.1
Published:2009
稿件说明:
移动端阅览
WEI Xin-lao, XUE Qing-hui, WANG Yong-hong, et al. Research on Middle Frequency Voltage Test Technique Used in Turn-to-turn Insulation Test for Pole Coils of Large Electrical Machines[J]. 2009, 14(2): 50-54.
DOI:
WEI Xin-lao, XUE Qing-hui, WANG Yong-hong, et al. Research on Middle Frequency Voltage Test Technique Used in Turn-to-turn Insulation Test for Pole Coils of Large Electrical Machines[J]. 2009, 14(2): 50-54.DOI:
Research on Middle Frequency Voltage Test Technique Used in Turn-to-turn Insulation Test for Pole Coils of Large Electrical Machines
Beginning an analysis of the shortcomings of present methods used to test turn-to-turn insulation of pole coil of large electrical machines
the frequency distribution of the turn-to-turn voltage in pole coil is researched at the first by a distribution circuit model of the pole coil.Appropriate high limit of frequency of the testing voltage source is determined by a circuit simulation analysis made for a typical pole coil.Combining of high power electronic switching technique and parallel resonance skill of...