The visualized statistics of the temperature profile factors (PF) at exits in an annular combustor and its sectors have been made. The results indicate that the number of heads in a sector has significant effect on PF. The empirical formulae for calculating all-ring combustor PF have been obtained from fitting of statistical data. The relative errors between the calculations with these formulae and the measurements in tests are less than0.045.