The Effects of Structural Parameters on Sealing Performance of Magnetic Fluid Seal
|更新时间:2026-07-07
|
The Effects of Structural Parameters on Sealing Performance of Magnetic Fluid Seal
Vol. 15, Issue 3, (2000)
作者机构:
北京航空航天大学机械工程及自动化学院,北京,100083
作者简介:
基金信息:
DOI:
CLC:
Published:2000
稿件说明:
移动端阅览
Zhao Guowei, Chi Changqing, Wang Zhishan, et al. The Effects of Structural Parameters on Sealing Performance of Magnetic Fluid Seal[J]. 2000, 15(3).
DOI:
Zhao Guowei, Chi Changqing, Wang Zhishan, et al. The Effects of Structural Parameters on Sealing Performance of Magnetic Fluid Seal[J]. 2000, 15(3).DOI:
The Effects of Structural Parameters on Sealing Performance of Magnetic Fluid Seal
The effects of structural parameters on the performance of magnetic fluid seal are researched on the basis of magnetic field analysis.The parameters include seal gap
structural parameters of pole tooth
structural parameters of permanent magnet and the number of teeth on the pole.In the process of magnetic field analysis
magnetic field method and unequally spaced net finite difference method are used to obtain accurate data.A qualitative explanation to the data is given by magnetic circuit analysis.In order to testify the theoretical research
an optimized magnetic fluid seal has been designed and tested.The experiment results show that the weight and size of the optimized seal are reduced by more than 50 percent.