Investigation on the Maximum Single Stage Loading Level of the Super- or Tran-Sonic Axial Flow Fans and Compressors
|更新时间:2026-07-07
|
Investigation on the Maximum Single Stage Loading Level of the Super- or Tran-Sonic Axial Flow Fans and Compressors
Vol. 17, Issue 5, (2002)
作者机构:
北京航空航天大学动力系,北京,100083
作者简介:
基金信息:
DOI:
CLC:
Published:2002
稿件说明:
移动端阅览
ZHU Guo dong, LI Pei jun, SHAN Peng. Investigation on the Maximum Single Stage Loading Level of the Super- or Tran-Sonic Axial Flow Fans and Compressors[J]. 2002, 17(5).
DOI:
ZHU Guo dong, LI Pei jun, SHAN Peng. Investigation on the Maximum Single Stage Loading Level of the Super- or Tran-Sonic Axial Flow Fans and Compressors[J]. 2002, 17(5).DOI:
Investigation on the Maximum Single Stage Loading Level of the Super- or Tran-Sonic Axial Flow Fans and Compressors
The quest for higher stage pressure ratio has been promoted by engine researchers.But in the multi stage fan and compressors
the rise in total and static pressures of a single stage axial flow compressor is constrained by many factors.The maximum stage loading level has a limitation.Using a simplified stage model
this paper investigates this level of a super or tran sonic single stage axial flow compressor under the conditions of the widest rotor stator matching and the stage matching.The paper concludes that the stage pressure ratio must be less than 37 when considering only the theoretical loading mechanism.Meanwhile it gives several graphs to exhibit the influencing strength of each constraint.