Endwall Heat Transfer and Film Cooling Measurements in a Turbine Cascade with Injection Upstream of Leading Edge
|更新时间:2026-07-07
|
Endwall Heat Transfer and Film Cooling Measurements in a Turbine Cascade with Injection Upstream of Leading Edge
Vol. 16, Issue 3, (2001)
作者机构:
1. 西北工业大学航空动力与热力工程系,陕西,西安,710072
2. Rolls Royce plc.,P.O.Box 31,Derby,UK,DE24 8BJ
作者简介:
基金信息:
DOI:
CLC:
Published:2001
稿件说明:
移动端阅览
LIU Gao-wen, LIU Song-ling, ZHU Hui-ren, et al. Endwall Heat Transfer and Film Cooling Measurements in a Turbine Cascade with Injection Upstream of Leading Edge[J]. 2001, 16(3).
DOI:
LIU Gao-wen, LIU Song-ling, ZHU Hui-ren, et al. Endwall Heat Transfer and Film Cooling Measurements in a Turbine Cascade with Injection Upstream of Leading Edge[J]. 2001, 16(3).DOI:
Endwall Heat Transfer and Film Cooling Measurements in a Turbine Cascade with Injection Upstream of Leading Edge
Detailed heat transfer measurements were conducted on the endwall surface of a large scale low speed turbine cascade with single and double row injection on the endwall upstream of leading edge.Local film cooling effectiveness and heat transfer coefficient with coolant injection were determined at blowing ratio 1
2 and 3.In conjuction with the previous measurement flow field
the behaviours of endwall film cooling and heat transfer were studied.The results show that endwall film cooling effectiveness is influenced to a great extent by the secondary flow and the coverage of the coolant on the endwall is mainly determined by blowing ratio.An uncovered triangle shaped area with low effectiveness close to pressure side could be observed at low blowing ratio injection.The averaged effectiveness increases significantly when injecting at medium and high blowing ratio
and quite uniform coverage of coolant on the endwall could be achieved.The averaged effectiveness could be doubled in case of double row injection.It was also observed that coolant injection made the overall averaged heat transfer rate increase remarkably with blowing ratio and then made the thermal loads on the endwall decrease effectively.Large increments of heat transfer rate could be happened at cascade entrance and exit and in the area near suction surface.