Experimental Investigation of the cooling performance of lamilloy using infrared thermal imaging technique
|更新时间:2026-07-07
|
Experimental Investigation of the cooling performance of lamilloy using infrared thermal imaging technique
Vol. 23, Issue 4, (2008)
作者机构:
1. 中国科学技术大学热科学及能源工程系,合肥,230027
2. 中国航空工业第一集团公司 沈阳发动机设计研究所,沈阳,110015
作者简介:
基金信息:
DOI:
CLC:
Published:2008
稿件说明:
移动端阅览
MA Long, WANG Jian-hua, WU Xiang-yu, et al. Experimental Investigation of the cooling performance of lamilloy using infrared thermal imaging technique[J]. 2008, 23(4).
DOI:
MA Long, WANG Jian-hua, WU Xiang-yu, et al. Experimental Investigation of the cooling performance of lamilloy using infrared thermal imaging technique[J]. 2008, 23(4).DOI:
Experimental Investigation of the cooling performance of lamilloy using infrared thermal imaging technique
To investigate the cooling performance of laminated configuration
an infrared thermal imaging technique was used in the experiments with true size configuration.The diameters of film hole
columniation and impingement hole were 0.5
0.8 and 0.8mm respectively
the chamber height and total thickness of the configuration were 0.8 and 2.6mm respectively
the ratio of the hole and culmination was 1∶4∶1.To measure surface temperature exactly
a thermocouple with high accuracy was used
and a correction relationship was established.To describe the integral cooling effect
an algorithm of thermal imaging signal was used for processing image digital signal.The experiments were carried out at a hot gas wind tunnel
and the results present the influence of coolant injection rate on the cooling performance of the laminated configuration.It is demonstrated that the infrared thermal imaging technique is effective method to study cooling performance of laminated configurations.