Investigation of acceleration factor for pre-corrosion fatigue degradation:model and analysis
|更新时间:2026-07-07
|
Investigation of acceleration factor for pre-corrosion fatigue degradation:model and analysis
Vol. 23, Issue 7, (2008)
作者机构:
北京航空航天大学 航空科学与工程学院,北京,100083
作者简介:
基金信息:
DOI:
CLC:
Published:2008
稿件说明:
移动端阅览
HE Xiao-fan, YANG Hong-yuan, LIU Wen-ting. Investigation of acceleration factor for pre-corrosion fatigue degradation:model and analysis[J]. 2008, 23(7).
DOI:
HE Xiao-fan, YANG Hong-yuan, LIU Wen-ting. Investigation of acceleration factor for pre-corrosion fatigue degradation:model and analysis[J]. 2008, 23(7).DOI:
Investigation of acceleration factor for pre-corrosion fatigue degradation:model and analysis
The acceleration corrosion factor(ACF) for accelerated corrosion test under service or natural exposed environment is the most important parameter in the accelerated corrosion test(ACT).The material property was degraded seriously in pre-corrosion environment
and the corrosion damage was characterized by fatigue strength.So
the acceleration factor was defined as the ratio of fatigue strength in different environments
and the expression was proposed in consideration of the degradation process of fatigue strength with corrosion time.To evaluate the fatigue property
the pre-corrosion fatigue life was assumed to follow the two-parameter Weibull distribution
the detail fatigue rating(DFR) method in pre-corrosion environment was proposed
and the relationship between the DFRand the corrosion time was expressed as an exponential function.The acceleration corrosion factor based on the DFRwas proposed by comparing the degradation process in accelerated corrosive environment and the natural exposed environment
and was proved to be a constant regardless of corrosion time.Finally
the typical ACFof LY12CZ Aluminum alloy specimen was calculated.