This paper presents detail measurements of film cooling effectiveness in a flat plan for a row double fan-shaped holes.The streamwise angle of hole was 45°and the diameter of hole was d.The pitch-to-diameter ratio(p/d) contained 2
3 and 4.The momentum flux ratios varied from 1 to 4 and the turbulence level contained 0.4% and 8%.The result indicated that the double fan-shaped holes made significant improvement of film cooling effectiveness compared with the round holes.The variety of the p/d had great effects on film cooling effectiveness.Increasing the momentum flux ratio lead to large improvement of film cooling effectiveness at the p/d=2
while the momentum flux ratio had small effects on it at the p/d=4.The enhancement of turbulence level lead to obvious decrease in film cooling effectiveness when p/d is large and the momentum ratio is high.