A pulse detonation engine(PDE) with diameter and length of 61mm and 1140mm respectively
was used to get the heat loads of detonation tubes which were designed into two types.The first one is that its heat transfer was controlled by natural convection and thermal radiation
and the other one was mainly influenced by forced convection.The same relations between heat load and working frequency were acquired in two conditions
namely
the heat load increased along with the increase of working frequency.However
with the doubling of the frequency from 20Hz to 40Hz(or from 25Hz to 50Hz) of the detonation tube
the heat load increased more than 100%.In addition
the vaporizing rate of kerosene was got at different frequencies
providing a reference for the design of PDE evaporator.
Research on heat load for main propulsion direct drive PMM of all-electric UAV
Experiment on combustion characteristics of-heptane droplets in micro-tube
Effect of inlet temperature and equivalence ratio on working process of pulse detonation engine
Comparative ignition characteristics of ethylene and gasolene in multi-cycle pulse detonation engine
Related Author
Guodong XIA
Ran LI
Dandan MA
Jiahao WANG
FENG Gui-hong
WANG Sen
ZHANG Bing-yi
WANG Ning-fei
Related Institution
Key Laboratory of Enhanced Heat Transfer and Energy Conservation, Ministry of Education,Beijing Key Laboratory of Heat Transfer and Energy Conversion, Faculty of Environment and Life, Beijing University of Technology
School of Automatic Control Engineering, Shenyang Institute of Engineering
Special Motor and High Voltage Apparatus Key Laboratory of Education Ministry, School of Electrical Engineering, Shenyang University of Technology
School of Aerospace Engineering, Beijing Institute of Technology
National Key Laboratory of Transient Physics, Nanjing University of Science and Technology