Predicting method for the performance of constant area isolator under back pressure
|更新时间:2026-07-07
|
Predicting method for the performance of constant area isolator under back pressure
Vol. 24, Issue 11, (2009)
作者机构:
南京航空航天大学能源与动力学院内流研究中心,南京,210016
作者简介:
基金信息:
DOI:
CLC:
Published:2009
稿件说明:
移动端阅览
YUAN Hua-cheng, LIANG De-wang, GUO Rong-wei, et al. Predicting method for the performance of constant area isolator under back pressure[J]. 2009, 24(11).
DOI:
YUAN Hua-cheng, LIANG De-wang, GUO Rong-wei, et al. Predicting method for the performance of constant area isolator under back pressure[J]. 2009, 24(11).DOI:
Predicting method for the performance of constant area isolator under back pressure
The flow filed in the isolator of a typical hypersonic inlet was simulated with uniform and non-uniform(with oblique shock) inflow.The pressure-temperature-Mach number at isolator exit relationship was investigated
the relationship of each other was presented
and all of those were independent of the isolator length.The predicting methods of the performance for constant area isolator under back pressure were studied
and doable predicting method of isolator under back pressure was presented.The concept of maximum pressure capability was developed when the back pressure was greater than the maximum pressure capability with unstarting of inlet.It's observed that the maximum pressure capability has relationship with the Mach number of the isolator exit with no back pressure.The predicting methods of maximum pressure capability for constant area isolator were presented.The maximum pressure-isolator length relationship was also presented.