Research on error analysis and correction of infrared temperature measurement for curved surface
|更新时间:2026-07-07
|
Research on error analysis and correction of infrared temperature measurement for curved surface
Vol. 25, Issue 2, (2010)
作者机构:
1. 南京航空航天大学 能源与动力学院,南京,210016
2. 中国航空工业集团公司 沈阳发动机设计研究所,沈阳,110015
作者简介:
基金信息:
DOI:
CLC:
Published:2010
稿件说明:
移动端阅览
CHANG Guo-qiang, CHANG Hai-ping, WANG Yin-hui, et al. Research on error analysis and correction of infrared temperature measurement for curved surface[J]. 2010, 25(2).
DOI:
CHANG Guo-qiang, CHANG Hai-ping, WANG Yin-hui, et al. Research on error analysis and correction of infrared temperature measurement for curved surface[J]. 2010, 25(2).DOI:
Research on error analysis and correction of infrared temperature measurement for curved surface
Experiments and theory analysis were carried out to investigate the characteristics of temperature measurement using thermal imager for curved surface.According to the theory of infrared thermometry techniques
the infrared radiation characteristics of curved surface essentially have no difference with flat surface
both of which can be described by the same mathematics expression.The essential reason which induces the measuring error of infrared thermal imagery for curved surface is that equivalent face of the measured surface no longer satisfies the diffuse body hypothesis
owing to too large included angle of the normal direction of curved surface and the measuring direction of infrared thermal imagery.The temperature measuring accuracy can be improved by measuring the local emissivity for the region where the diffuse body hypothesis is invalid for its equivalent face.