Numerical simulation on cooling characteristics of an afterburner fuel injector with double-wall construction
|更新时间:2026-07-07
|
Numerical simulation on cooling characteristics of an afterburner fuel injector with double-wall construction
Vol. 24, Issue 8, (2009)
作者机构:
北京航空航天大学 能源与动力工程学院,北京,100191
作者简介:
基金信息:
DOI:
CLC:
Published:2009
稿件说明:
移动端阅览
LI Rui-ming, YAN Bao-hua, FAN Wei-jun, et al. Numerical simulation on cooling characteristics of an afterburner fuel injector with double-wall construction[J]. 2009, 24(8).
DOI:
LI Rui-ming, YAN Bao-hua, FAN Wei-jun, et al. Numerical simulation on cooling characteristics of an afterburner fuel injector with double-wall construction[J]. 2009, 24(8).DOI:
Numerical simulation on cooling characteristics of an afterburner fuel injector with double-wall construction
The performance of the cooling air flow extracted from the bypass duct to cool a new fuel injector with double-wall construction for afterburner was simulated numerically.The results of the simulation and the experiment agree with each other very well.The temperature distribution of outer casing and inner pipe
and cooling air rate extracted from the bypass duct were obtained by calculations under four working conditions of the afterburner.It shows that the type of afterburner fuel injector can extract enough cooling air from the fan stream and can effectively decrease the temperature of the wall of fuel injector.