Experimental investigation on flow rate and mixing characteristics of splash platelet injector element
|更新时间:2026-07-07
|
Experimental investigation on flow rate and mixing characteristics of splash platelet injector element
Vol. 24, Issue 6, (2009)
作者机构:
1. 北京航空航天大学 宇航学院,北京,100191
2. 中国航天科技集团公司,北京,100037
3. 西安航天动力研究所,西安,710100
作者简介:
基金信息:
DOI:
CLC:
Published:2009
稿件说明:
移动端阅览
LEI Fan-pei, ZHANG Zhen-peng, YAO Ming-ming, et al. Experimental investigation on flow rate and mixing characteristics of splash platelet injector element[J]. 2009, 24(6).
DOI:
LEI Fan-pei, ZHANG Zhen-peng, YAO Ming-ming, et al. Experimental investigation on flow rate and mixing characteristics of splash platelet injector element[J]. 2009, 24(6).DOI:
Experimental investigation on flow rate and mixing characteristics of splash platelet injector element
The flow rate and mixing characteristics of splash platelet injector element with a typical triangular lumen were experimentally investigated by using a collecting device with an area of 16cm×16cm.The effect of main configuration parameters
such as expending angle and relative thickness
on flow coefficient and mixing efficiency factor were obtained.The results show that
flow coefficient and mixing efficiency factor increase firstly and then decrease with the increase of expending angle.Both of them could reach their maximum value of 0.773 and 82.6% when expending angle is at the range of 60° to 75°.It is also found that the relative thickness has great influence on the flow coefficient and mixing efficiency.