Experimental study on flow in the impeller of low specific speed pump using particle image velocimetry
|更新时间:2026-07-07
|
Experimental study on flow in the impeller of low specific speed pump using particle image velocimetry
Vol. 25, Issue 9, (2010)
作者机构:
南京工业大学 机械与动力工程学院,南京,210009
作者简介:
基金信息:
DOI:
CLC:
Published:2010
稿件说明:
移动端阅览
SHAO Chun-lei, GU Bo-qin, HUANG Xing-lu, et al. Experimental study on flow in the impeller of low specific speed pump using particle image velocimetry[J]. 2010, 25(9).
DOI:
SHAO Chun-lei, GU Bo-qin, HUANG Xing-lu, et al. Experimental study on flow in the impeller of low specific speed pump using particle image velocimetry[J]. 2010, 25(9).DOI:
Experimental study on flow in the impeller of low specific speed pump using particle image velocimetry
pump experimental facility and test scheme were introduced.An experimental investigation of flow in the impeller was conducted at three different flow rates on three measurement planes by means of PIV.The velocity vector distribution was obtained.The velocity distribution in circumferential and axial directions and the influence of flow rate on the distribution were investigated.The results indicate that
the velocity near the suction surface decreases slightly
and that near the pressure surface changes dramatically with decreasing flow rate.The fluid flows back near the pressure surface when the flow rate reaches 0.6Qd.At the outlet of impeller
the flow rate has no significant influence on the direction of relative velocity.The velocity in the impeller passage distributes homogeneously in axial direction.The absolute velocity shows an increasing trend in radial direction.The circumferential component of nondimensional absolute velocity decreases from the pressure surface to the suction surface
and also increases with the decline of flow rate.The results provide valuable information for the design of impeller and experimental study on flow in the centrifugal pump.