Experimental investigations were carried out to study the rotating film cooling characteristics at different blowing ratios in a 1.5-turbine stage.The mainstream Reynolds number Reg is 1.6451×105 in the experiment.CO2 acts as a coolant with mainstream jet density ratio of 1.57.Turbine speed is 475r/min
and the rotation number is 1.901.The blowing ratio varies from 0.5 to 2.0.By using steady-state liquid crystal method
the results show that: (1) On pressure side
the film cooling efficiency and the film coverage increase
the deflection angle of film trajectory decreases with the increasing blowing ratio. (2) On suction side
the film cooling efficiency and the film coverage first increase and then decrease
the film trajectory has no obvious deflection angle with the increasing blowing ratio. (3) The curvature radius of jet flow affects the adhesion of film on the wall.