Serial experiments were conducted to obtain the flow and heat transfer characteristics of boiling two-phase pipe flow under different diameters and side load.By analyzing the measured parameters such as pressure drop
Reynolds number
void fraction
heat flux and heat transfer coefficient in the test pipe
the effects of side load and pipe diameter on the characteristics of boiling two-phase flow were studied.The results show that the greater the side load
the higher the pressure drop
the heat dissipation
and the lower the flow rate
the void fraction and the heat flux.Dynamic load increases the heat transfer coefficient for single-phase water flow.However for boiling two-phase flow
with the increase in side load
the heat transfer coefficient decreases somewhat first
then increases and finally decreases again.Pipe diameter also has great influence on Reynolds number
pressure drop
void fraction and heat dissipation.The pipe with smaller diameter has a larger flow resistance