Combined heating method of low speed and high/middle temperature gas flow for thermal test of tip wedge structure
|更新时间:2026-07-07
|
Combined heating method of low speed and high/middle temperature gas flow for thermal test of tip wedge structure
Vol. 28, Issue 2, (2013)
作者机构:
北京航空航天大学 航空科学与工程学院 人机工效与环境控制重点学科实验室,北京,100191
作者简介:
基金信息:
DOI:
CLC:
Published:2013
稿件说明:
移动端阅览
DONG Su-jun, LI Zhi-jie, WANG Jun. Combined heating method of low speed and high/middle temperature gas flow for thermal test of tip wedge structure[J]. 2013, 28(2).
DOI:
DONG Su-jun, LI Zhi-jie, WANG Jun. Combined heating method of low speed and high/middle temperature gas flow for thermal test of tip wedge structure[J]. 2013, 28(2).DOI:
Combined heating method of low speed and high/middle temperature gas flow for thermal test of tip wedge structure
The big temperature gradient in hypersonic tip wedge structure was calculated and simulated
and key thermal simulation parameters were presented.Since the single spout heating method can not simulate the heat flux density satisfactorily on the rear plate
a dual-mode heating method was developed to solve this problem
covering a high temperature flow with small spout in the center enveloped by a lower temperature flow.A typical hypersonic condition was simulated using CFD method.It shows that this new heating method can accurately simulate the hypersonic heat flux distribution of the tip wedge by effectively meliorating the heat flux distribution on the rear plate and maintaining the high heat flux density on the stagnation zone.The simulation of transient temperature distribution and big temperature gradient in the interior of tip wedge structure also gets very good results to support this strategy.Meanwhile
the dual-mode heating method can not only greatly reduce the spout size and speed of high temperature flow
but also greatly improve the test ability of electric arc wind tunnel to satisfy larger size of tip wedge structure.