Method of measuring 3-D unsteady flow at exits of transonic compressor rotor passages using a two-hole tip-wedge pressure probe
|更新时间:2026-07-07
|
Method of measuring 3-D unsteady flow at exits of transonic compressor rotor passages using a two-hole tip-wedge pressure probe
Vol. 27, Issue 10, (2012)
作者机构:
1. 北京航空航天大学 能源与动力工程学院 航空发动机气动热力国家级重点实验室,北京,100191
2. 中国航空工业集团公司 沈阳发动机设计研究所,沈阳,110015
作者简介:
基金信息:
DOI:
CLC:
Published:2012
稿件说明:
移动端阅览
LI Jing-yang, MA Hong-wei, HE Xiang. Method of measuring 3-D unsteady flow at exits of transonic compressor rotor passages using a two-hole tip-wedge pressure probe[J]. 2012, 27(10).
DOI:
LI Jing-yang, MA Hong-wei, HE Xiang. Method of measuring 3-D unsteady flow at exits of transonic compressor rotor passages using a two-hole tip-wedge pressure probe[J]. 2012, 27(10).DOI:
Method of measuring 3-D unsteady flow at exits of transonic compressor rotor passages using a two-hole tip-wedge pressure probe
A method of measuring 3-D(three-dimensional) dynamic flow field with a two-hole fast-response tip-wedged cylindrical pressure probe has been developed and applied in a transonic multistage axial compressor.The measuring method was based on the four-hole pneumatic probe and realized by rotating the probe at three angular positions.The least square fitting method was used to process the calibration data and the optimal fitting order was determined through optimizing the fitting error.In this way
the approximate functions of the flow parameters with higher accuracy were obtained.The probe is characterized by small size
high frequency
wide measurement range and high measurement precision compared with other similar probes.The unsteady flow field at the exit of the rotor was measured utilizing phase locked technique.The measurement results reflect the flow features of the compressor rotor
providing distributions of flow yaw angle
pitch angle
total pressure and Mach number at the rotor exit
which is the key to optimize the stage performance.Therefore
it verifies the engineering application of this fast-response pressure probe measuring technique which can provide a feasible measurement method for the flow diagnoses in transonic multistage compressors.