The influence of aperture ratio and center distance of a gas turbine combustor mixing system on outlet temperature field was studied experimentally.Experimental results indicate:the outlet temperature distribution coefficient reduces gradually with the increase of aperture ratio.But too large aperture ratio will lead to partial obstruction and also hot spot temperature rise;aperture ratio does not change the radial temperature distribution curve shape
but only bring about shift of its position.Relative center distance and the radial temperature distribution coefficient have a strong correlation
too large (more than 0.33) or too small (less than 0.29) is not helpful for dilution.Relative center distance of 0.31 and aperture ratio of 0.32 are basically reasonable in this case.
Analysis of low-swirl injector emissions and combustion stabilization
Experimental study on outlet temperature field in multipoint injection combustor-sector
Experimental study on outlet temperature field for combustor of heavy-duty gas turbine
Effect of oil⁃gas matching on combustor instability
Recent advances on jet atomization in cryogenic liquid rocket combustion chamber
Related Author
ZHANG Chi
YU Bo-wen
YANG Qian
LIU Cheng-chuan
LIN Yu-zhen
ZHANG Zhen-kui
ZHONG Hua-gui
FENG Da-qiang
Related Institution
National Key Laboratory of Science and Technology on Aero-Engine Aero-Thermodynamics,School of Energy and Power Engineering,Beijing University of Aeronautics and Astronautics
China Gas Turbine Establishment, Aviation Industry Corporation of China, Jiangyou Sichuan
School of Aerodynamics and Energy Engineering,Shenyang Institute of Aeronautical Engineering
Sichuan Gas Turbine Establishment,Aero Engine Corporation of China
School of Energy and Power Engineering,Huazhong University of Science and Technology