Non-invasive on-line diagnosis method for winding faults of main transformer in AC electric locomotive
To detect the fault of the main transformer windings for AC locomotive without changing the original structure of the locomotive system
a non-invasive on-line winding fault diagnosis method for the main transformer is proposed. Proved by the mathematical theory
the relationship between ΔV-i1 is a diagonal ellipse whose center is located at the origin of rectangular coordinate system. The related parameters of the ellipse vary with the change of the winding faults. Then
the feasibility and effectiveness of the proposed method are verified by experiment through dSPACE simulations. The results show that with the increase of short circuit percentage
the area of ellipse increases and the centrifugal rate decreases. When the axial displacement is increased
the centrifugal rate increases
while the elliptical length
short axis and its area decrease. When short-disk occurs
the elliptical short axis decreases and the inclination angle changes obviously. By comparing the ΔV-i1 trajectory under normal and fault condition