Correction and hardware verification of echo centroid algorithm for airborne LADAR
Aiming at the real-time detection and weak echo signal characteristics of push-broom airborne laser detection and ranging (LADAR) system
one algorithm for echo time abstracting is researched based on Gauss normal echo signal. The algorithm is fast
precise and easy to design in hardware
which achieves high precision distance detection as a result. The existing problems and accuracy of the traditional waveform centroid algorithm are analyzed. In order to reduce the influence of the data precision and noise interference on the hardware
a corrected approach based on the median method is proposed
which can effectively weaken the layered phenomenon in hardware implementation of algorithm. A mathematical model is established by MATLAB and the simulation experiment is carried out. The simulation results show that the corrected centroid algorithm has better robustness compared with the traditional centroid algorithm and Gaussian fitting algorithm. The accuracy can reach 0.5 ns
which is 45% higher than that of the traditional centroid when the SNR is 5 dB. The proposed algorithm can achieve higher accuracy than Gaussian's with the SNR becoming greater
which reaches 0.01 ns theoretically. The corrected algorithm is simple and efficient. In addition
real-time judgments and correction on the results of the centroid are made without increasing the complexity of the system. Owing to the simplicity of the algorithm
it is suitable for transplanting to FPGA platform. The algorithm has been utilized for push-broom airborne LADAR system information processing circuit. The results of experiment verify the validity of the theoretical analyses and show that the algorithm can achieve the ranging accuracy of ±7.5 cm
which meets the real-time requirements in practical application.