YU Qiong, SUN Jiaqiu, YUAN Weihang. Experimental study on bond behavior between ribbed steel bars and sleeve constrained grouting material[J]. 2018, 50(12): 98-106.
DOI:
YU Qiong, SUN Jiaqiu, YUAN Weihang. Experimental study on bond behavior between ribbed steel bars and sleeve constrained grouting material[J]. 2018, 50(12): 98-106.DOI: 10.11918/j.issn.0367-6234.201711108.
Experimental study on bond behavior between ribbed steel bars and sleeve constrained grouting material
To study the bond behavior between the ribbed steel bars and sleeve constrained grouting material
pull-out tests were conducted on 45 specimens. The failure modes
ultimate bearing capacity and ultimate average bond strength were studied. The influences of bar diameter
anchorage length and sleeve dimension on the ultimate average bond strength were discussed. Bond-slip constitutive relations between the ribbed steel bars and grout constrained by sleeve were fitted. Equations were proposed for calculating the characteristic bond strengths and their corresponding slip value. Critical anchorage lengths
at which length bar broke or yielded and bar-grout slippage occurred at the same time
were calculated. The test results showed that with the increase of the bar diameter
the ultimate bearing capacity increased
and the ultimate average bond strength increased as a whole. With the increase of anchorage length
the ultimate bearing capacity increased
but the ultimate average bond strength decreased. In the range from 13.78% to 18.51%
the increase of steel content had little positive effect on the average bond strength. Because no coarse aggregate is contained in the grout
the slip value corresponding to the ultimate average bonding strength when the steel bar was anchored in grout was greater than that when the steel bar was anchored in concrete. Based on the energy analysis of the bond slip curve
it concluded that as the diameter and anchorage length of the bar increased
the brittleness coefficient of the specimen decreased generally
indicating the increase of the specimen’s ductility. Due to the confinement of the sleeve