To study the effect of multiimpact damage and highcycle shear fatigue on the damage evolution
buckling behavior and failure modes of stiffened composite panels
nine stiffened composite panels were manufactured with similar configurations
and the impact test
highcycle shear fatigue test and residual shear strength test were designed. During the multiimpact and highcycle shear fatigue tests
the damaged zones were detected by the ultrasonic Cscan system. Cscan images indicated that the length and width of damaged zones increased with the increasing number of cycles. Compared with initial undamaged specimen
the average failure load of specimens with multiimpact damage and highcycle shear fatigue declined about 50%. Furthermore
the failure modes of the specimens were also affected by the initial damage caused by impact or fatigue. For the impact and fatigue specimens
the deformation of local buckling skin appeared
and the failure cracks were much near the impact damaged zones.