The effect of vibration environment on critical heat flux (CHF) of spray cooling was studied. The point-based CHF model under vibration environment was built by defining factor which represented the degree of deviating from the inscription state
based on the CHF model in normal environment. Three operation modes were compared
and the operation mode one had 0.98% and 1.17% increase in the period-average CHF compared with the others. In the operation mode one
the curve of CHF showed a bimodal structure
and the minimum CHF of the second half of period was larger than that of the first half of period. The minimum CHF was 3.02% lower than the maximum CHF. The larger vibration amplitude led to the greater decrease of the CHF. The average CHF with 1.0mm amplitude was 1.74% lower than that with 0.2mm amplitude. The influence of spray angle was discussed. The average CHF showed 4.83% and 16.21% drop in 55.8° and 90° cases respectively
compared with 30° spray angle case. The difference between the minimum CHF of the second half of period and maximum CHF was smaller in larger spray angle case. Using nozzle with small spray angle could reduce the negative effect of vibration.
Experiment on the thermal management performance of phase change material under vibration environment
Investigation on experimental correlations for aircraft spraycooling system in non-boiling area
考虑多源不确定性的复合材料风扇叶片高周疲劳失效概率评估
组合式弹性金属密封泄漏特性实验研究与结构优化
基于自适应MOMEDA滚动轴承故障特征提取方法
Related Author
罗叶刚
ZHOU Nian-yong
WANG Yu
JIANG Yan-long
REN Zhe-fan
SUN Cheng-bing
ZHENG Wen-yuan
Related Institution
College of Aerospace Engineering, Nanjing University of Aeronautics and Astronautics
Aviation Key Laboratory of Science and Technology on Aero Electromechanical System Integration, Nanjing Engineering Institute of Aircraft Systems, Jincheng, Aviation Industry Corporation of China