LIU Xupeng, SUN Qi, WANG Xiaoliang, XUE Xiusheng, YIN Dong. Design and application of an air-cooled probe for total pressure measurement at combustor outlet[J]. 航空动力学报, 2019, 34(1): 34-44.
doi: 10.13224/j.cnki.jasp.2019.01.005
LIU Xupeng, SUN Qi, WANG Xiaoliang, XUE Xiusheng, YIN Dong. Design and application of an air-cooled probe for total pressure measurement at combustor outlet[J]. 航空动力学报, 2019, 34(1): 34-44.DOI: 10.13224/j.cnki.jasp.2019.01.005.
doi: 10.13224/j.cnki.jasp.2019.01.005DOI:
Design and application of an air-cooled probe for total pressure measurement at combustor outlet
An air-cooled probe was designed for measurement of total pressure at combustor outlet; its cooling scheme combined the film cooling and convection cooling. With the aid of CFD technique
cooling effectiveness of the coolant jets at various blow ratios was compared; suitable blow ratios and configuration of film holes were chosen accordingly. The overall cooling performance of the probe was evaluated via CFD technique
the design was improved according to the simulation result
and the cooling effect of the leading edge was obviously strengthened by increasing the local coolant mass flow rate. The results of wind tunnel test indicated that
between Mach numbers 0.2 and 0.4
the probe achieved a high accuracy at various attack angles. The probe was utilized in an annular combustor rig test
the highest temperature reached 1760K and total pressure reaches 1036kPa. The result of rig test demonstrates that the coolant film distribution consistent appropriately with the CFD results.
Abstract
An air-cooled probe was designed for measurement of total pressure at combustor outlet; its cooling scheme combined the film cooling and convection cooling. With the aid of CFD technique
cooling effectiveness of the coolant jets at various blow ratios was compared; suitable blow ratios and configuration of film holes were chosen accordingly. The overall cooling performance of the probe was evaluated via CFD technique
the design was improved according to the simulation result
and the cooling effect of the leading edge was obviously strengthened by increasing the local coolant mass flow rate. The results of wind tunnel test indicated that
between Mach numbers 0.2 and 0.4
the probe achieved a high accuracy at various attack angles. The probe was utilized in an annular combustor rig test
the highest temperature reached 1760K and total pressure reaches 1036kPa. The result of rig test demonstrates that the coolant film distribution consistent appropriately with the CFD results.