In order to explore the cooling application of microchannels in gas turbine lower emissions combustors
the effects of wall cooling with microchannels on the performances of swirl combustor were studied with water as the coolant. Results showed that the microchannels had significant cooling effect on the combustor walls with high temperature. When Reynolds number of coolant passing through microchannels was less than 350
the increase of Reynolds number of coolant had a significant influence on the decrease of wall temperature
but when Reynolds number was greater than 350
the decrease of wall temperature was almost negligible as the flow rate increased. At fixed values of air mass flow rate and equivalent ratio
the flame structures characterized by CH* chemiluminescence signal hardly changed as Reynolds number of coolant increased
but swirl flame contained yellow sparks or even yellow flame
leading to incomplete combustion in a relatively high Reynolds number. As Reynolds number of coolant increased
the heat transfer rate of wall was raised
which enhanced the interaction between the flame and heat transfer of microchannels during combustion and led to results such as bigger heat loss on the flame surface
more CO emission
less NOx emission and lower overall efficiency of swirl combustion.