XU Lin-feng, ZHU Dong-bai, MAO Qi-wu, et al. A Research of Reactor Loss Accurate Measurement Methods[J]. 2016, 21(2): 90-93.
DOI:
XU Lin-feng, ZHU Dong-bai, MAO Qi-wu, et al. A Research of Reactor Loss Accurate Measurement Methods[J]. 2016, 21(2): 90-93.DOI: 10.15938/j.jhust.2016.02.016.
A Research of Reactor Loss Accurate Measurement Methods
摘要
通过测量电抗器的端电压和端电流
参考CPU提供的标准正弦和余弦函数
从而提取电压与电流的有功和无功分量.根据基波电压和电流的相位关系
推导出电抗器损耗计算公式.由于损耗计算值每个周期波动较大
将每周期计算结果利用巴特沃斯滤波器去抖后
实测结果表明
相角误差小于0.72度
损耗波动值小于0.2%
说明该方法切实可行
测量结果准确可靠.
Abstract
According to the standard sine and cosine functions provided by the CPU
it is necessary to calculate the active and reactive components of the fundamental voltage and current by measuring the reactor terminal voltage and current. According to the phase relationship between the fundamental voltage and current
reactor loss formula can be deduced. Due to the loss calculation value for each cycle fluctuations
it is necessary to limit the calculating result waved of the reactor loss by using the digital Butterworth filter. Test results show that the error of the phase angle is less than 0. 72 degree
the error of the fundamental loss is less than 0. 2%
indicating that the method is feasible and the measurement results are accurate and reliable.