A Statistical-Based Digital Background Calibration for Pipelined ADC[J]. 2011, 28(2): 69-73.DOI:
一种基于统计的流水线ADC数字后台校准方法
摘要
高精度流水线ADC的设计需要校准技术来提高其转换精度.基于统计的数字后台校准方法无需校准信号
直接通过对输出的统计得到误差值的大小
将其从数字输出中移除从而消除了ADC输出非线性.将该校准方法应用于14 bit流水线ADC中
仿真结果表明校准后信噪失真比SNR为76.9 dB
无杂散动态范围SFDR为73.9 dB
有效精度ENOB从9 bit 提高到12.5 bit.
Abstract
Pipelined ADCs with high resolution need calibration technique to increase their conversion precision. The statistical-based digital background calibration technique presented here calculates the output error via statistic analysis
and then the error is subtracted from the ADC output. With this calibration architecture used in a 14-bit pipelined ADC
the simulation results show that after calibration the SNR is 76.9 dB