Asymmetry of rotor tip clearance in compressors always exists to some extent.To investigate the effects of rotor tip clearance asymmetry on compressor performances
a series of nonaxisymmetric tip clearance casing configurations were designed and experimented on a low speed
axial flow compressor with a single rotor.For each geometry
experiments were taken under both 5059 r/min and 8130 r/min conversion velocities.According to the experiments
several phenomena could be obtained:(1) With tip clearance asymmetry increasing
the stall points on compressor performance curves shifted to the lower right
compared with the solid casing and symmetric tip clearance.To evaluate such shifting effects quantitatively
two parameters were defined.(2) With tip clearance asymmetry increasing
the average stall performance was also decreased.(3) On the other hand
however
the size of the stall-unstall hysteresis loops on the performance map decreased with the increasing of the tip clearance asymmetry
which showed that it was easier for the compressor to recover from stall.As a whole
the experimental results showed that
such treated casings were detrimental to the compressor performances.