Numerical simulation has been used to investigate a cooling configuration of a guide turbine vane.This vane has outer sparse film cooling holes and inner impingement holes.In this paper
we mainly studied how different positions and diameters of the film cooling holes influenced the cooling efficiency on the pressure and suction sides of the vane;and discussed the cooling efficiency and uniformity of temperature distribution on the pressure and suction sides of the vane.The computational results show that
within the parameters used in this simulation
the increase in the film cooling hole diameters obviously improves the cooling efficiency on the pressure side of the vane
but the effect is more complicated on the suction side.Considering the cooling efficiency and the uniformity of temperature distribution on the pressure and suction sides of the vane
the position of the film cooling holes located on the front side of the chamber results in the best cooling efficiency.