The numerical simulation was used to study the effusion holes on the longitudinal wavy liner in the combustor.The investigation focused on the parameters affecting cooling effectiveness
including: opening ratio
height of ripple board
diameter of holes and height of cooling passage.Given the same total flow effusion from holes
the results show that the heat shield gets a higher average cooling effectiveness when the opening ratio is 3% compared with 6%;cooling effectiveness is sensitive to the height of ripple board