DONG Su-jun, QI Bin, LI Zhi-jie, et al. Approach and facility for aerodynamic thermal test by lower speed and high-temperature gas flow[J]. 2012, 27(5).
DONG Su-jun, QI Bin, LI Zhi-jie, et al. Approach and facility for aerodynamic thermal test by lower speed and high-temperature gas flow[J]. 2012, 27(5).DOI:
Comparability of flow parameters and surface heal flux density on a typical leading structure by these two heating approach was analyzed
it was demonstrated to be feasible of utilizing lower-speed and high-temperature gas flow as heating method for hypersonic aerodynamic thermal test.A new combined heating scheme composed of a lower-speed and high-temperature gas flow and quartz lights was proposed for hypersonic aerodynamic test of blunt cone’s.The newly-built aerodynamic thermal tester was designed with an efficient double-chamber vaporizing combustor
a new water-cooled pipe structure with thermal insulation sandwich of keramic material bearable high temperature
electric pre-heaters and twin-fule-supply scheme for the combustor.It can generate a hot gas of 2100K.The average gradient of radial temperature distribution of φ250mm nozzle is about 3K/mm.And the tester has auto-linear-control ability of temperature and the temperature difference is 46K.In a word
it can meet the urgent requirement for thermal test of high temperature and high heat flux of hypersonic vehicle flying by 24km height and mach number 6 speed.