且偏差达到1.0%时个别反演数据明显“失真”.③ k 反演计算误 差的标准差 y 与实验偏差 γ 满足 y =2285.2 γ2- 10.484 γ +0.0037的关系式; n 反演计算误差的标准差受实验偏差影响较小
但偏差导致反演 n 误差均超过20%.
Abstract
The spectral transmittance radio calculation model of glass- liquid hydrocarbon fuel-glass three layer slabs was developed based on ray trace method
and an inverse model was built to determine the thermal radiation property (k is extinction coefficient and n is refractive index) of liquid hydrocarbon fuel in the three layer slabs.The inverse model was retrieved
and was combined with Monte-Carlo method and area approach method.The thermal radiation property of heptane attained in the references was selected as the true values
and the spectral transmittance radio of the three layer slabs based on the direct model simulation was regarded as the experimental values.The thermal radiation property of Heptane was achieved by the inverse model
and then the effect of measurement error on the inverse results was also investigated.The results show that
(1) the standard deviation of k calculation error by the inverse model is less than 0.003%
and that of n is higher than 21%. (2) the effect of measurement error on the inverse results is urgent distinct
and some inversed calculation values are obviously when the measurement error is higher than 1%.(3) the standard deviation of k calculation error and measurement error y satisfy the equation which is y =2285.2 γ2-10.484 γ +0.0037.The effect of measurement error on the standard deviation of n calculation error is lower
however
the n calculation error is higher than 20% when the measurement error exists.