The experimental unit and correction method for estimation of performance of fuel distribution based on planar laser induced fluorescence (PLIF) method were established
and the correction method was validated. The comparisons between results of PLIF method and planar laser scattering (PLS) method indicate that
the results of PLS method overrepresents droplet concentration for droplets less than 50μm and PLIF is suitable for fuel distribution measurement. To make sure the quality of machining and performances of the atomizers
the distributions of droplets were evaluated comprehensively by PLIF method in terms of spray cone angle
non-uniformity of circumferential distribution and patternation index
and then
the results of eccentricity and grooves of different sizes for the poor droplets distribution show that
the factors for non-uniformity include the roughness of internal flow wall
roundness of nozzle and coaxiality of parts. The opening processes of spray cones in the direction of ejection were visualized by PLIF method at pressure differential of 0.14
0.25 and 2.5 MPa
respectively
and the droplets dispersed from annulus to round in cross-sectional plane with development of the spray. Furthermore
the rate of droplets dispersion increased with the growing pressure differential of fuel.