李琳莹, 李春生, 程言, et al. The proposalfor link design attenuation of optical fiber cable[J]. 2015, (1): 57-60.DOI:
关于光缆链路设计衰减值的建议
摘要
降低光纤衰减是提高系统容量和传输距离的有效方式。随着100G、400G通信系统的到来
对降低光纤衰减提出了新的要求
每一个0.01dB/km的进步对于系统都是至关重要的。目前的线缆设计及光缆规范中
一直将最大的成缆后单芯光纤衰减作为衡量指标
该指标表示的是单盘光纤的最坏值
未能客观体现光纤链路衰减的实际性能
更不能有效体现光纤衰减的进步。本文描述了在光缆网络设计中采用链路设计衰减值的重要性
探讨了光纤在成缆后的衰减变化规律
通过采用蒙特卡洛法来计算成缆后光纤链路衰减值
为系统设计合理利用光缆链路衰减提供参考。
Abstract
Reducing the fiber attenuation is an efficient way to improve the system capacity and transmission distance.With the arrival of 100 G
400G communication system
thenew requirements are put forward in term of the fiber attenuation.Any progressesof even 0.01dB/ km improvement are critical to the system.However
in the current optic fiber cable specification
the maximum attenuation of a single fiber after cabling has been as a metrics
which has not effectively reflected advancement in fiber attenuation.The paper introduces the necessity of specifying link design attenuation value
and applying link design attenuation valuein network design.The reasons for cabled fiber attenuation variationare reviewed.The link design attenuation valuefor optic fiber cable linkscalculated by Monte Carlo method can provide useful guidance to estimate the linked attenuation in system design with an acceptable degree of conservatism desired by network designersare also discussed.