YAN Bin, LI Hongbo, ZHANG Jie, et al. Forming limit of Ti-4Al-2V titanium alloy plate with different microstructures at room temperature[J]. 2020, 52(5): 148-156.
YAN Bin, LI Hongbo, ZHANG Jie, et al. Forming limit of Ti-4Al-2V titanium alloy plate with different microstructures at room temperature[J]. 2020, 52(5): 148-156.DOI: 10.11918/201906058.
Titanium alloys forming at room temperature has attracted increasing attention due to its low processing cost. As is known
titanium alloys with different microstructures present different forming properties. The forming limit diagram is the basis to study the material failure and forming ability in the numerical simulation of titanium alloy plate forming at room temperature. However
to obtain forming limit requires numerous experiments
which are expensive and time-consuming. In order to reduce the experimental cost and shorten the development cycle
a feasible progression-dependent method based on the finite element (FE) simulation was adopted to determine the process from localized necking to fracture
which was also used to predict the forming limit diagrams of TA17 titanium alloy plate with different microstructures. The FE simulation results of the forming limit were compared with those of uniaxial tensile test
punch bulging test
and round cup drawing test. The results verified the correctness of the FE simulation results. Moreover
the forming limits of three TA17 titanium alloys with different microstructures were compared
and the effect of microstructure on their forming limits at room temperature was analyzed. Results show that the TA17 titanium alloy with the equiaxed microstructure provided the best performance on the forming limit
which was also supported by the fractographs of the samples. This work sheds light on the research on the forming properties of titanium alloys microstructures produced by different heat treatment processes
and establishes a foundation for the subsequent work on the stamping of TA17 titanium alloys.