1. 哈尔滨工业大学 环境学院,哈尔滨,150090
2. 广东粤港供水有限公司,广东,深圳,518021
3. 深圳市拓安信计控仪表有限公司,广东,深圳,518100
纸质出版:2021
移动端阅览
高金良, 陈健勋, 郑成志, 等. 应用改进ICA-R算法的供水管网漏失量估计[J]. 哈尔滨工业大学学报, 2021,53(5):42-47.
GAO Jinliang, CHEN Jianxun, ZHENG Chengzhi, et al. Leakage estimation of water supply network by improved ICA-R algorithm[J]. 2021, 53(5): 42-47.
高金良, 陈健勋, 郑成志, 等. 应用改进ICA-R算法的供水管网漏失量估计[J]. 哈尔滨工业大学学报, 2021,53(5):42-47. DOI: 10.11918/201906060.
GAO Jinliang, CHEN Jianxun, ZHENG Chengzhi, et al. Leakage estimation of water supply network by improved ICA-R algorithm[J]. 2021, 53(5): 42-47. DOI: 10.11918/201906060.
漏失量作为城市供水管网漏损量的主要组成成分
可作为管网漏损控制的重要参考指标.现有漏失量计算方法存在准确度不高
计算过程复杂等问题
而盲源分离法具有数据需求量少
分析结果准确特点.针对盲源分离中约束独立成分分析(CICA)算法在漏失量估计中存在误收敛
限制盲源分离法进一步应用的问题
提出利用改进的带参考信号的独立成分分析(改进ICA-R)算法进行供水管网漏失量估计思路.对目标函数选取、信号处理过程进行分析说明
同时设计算例管网模型并搭建漏失实验平台验证算法分离效果
并与快速独立成分分析(FastICA)算法处理效果进行对比.采用皮尔逊相关系数评价漏失量分离效果
利用平均相对误差评价改进ICA-R分离精度.结果证明
使用改进ICA-R算法分离漏失量所得相关系数维持在90%附近
平均相对误差维持在15%以内
优于FastICA算法
该方法避免加装大量计量仪表
降低了漏失量计算成本
可为漏失量计算提供参考
便于各水司有针对性地采取漏损控制措施.
As the main component of the loss quantity of urban water supply network
the leakage quantity can be used as an important reference index for pipe network loss control. The existing calculation method of leakage is not accurate and the calculation process is complicated
whereas the blind source separation method needs less data and can achieve more accurate analysis results. However
the constrained independent component analysis (CICA) algorithm in blind source separation has the problem of misconvergence in the estimation of leakage quantity
which limits the further application of the blind source separation method. To solve this problem
an improved ICA-R algorithm was proposed to estimate the leakage of water supply network. The selection of objective function and signal processing were analyzed. An example pipe network was designed and the leakage experimental platform was built to verify the separation effect of the algorithm
and results were compared with the treatment effect of fast independent component analysis (FastICA). Pearson correlation coefficient was adopted to evaluate the effect of leakage separation
and average relative error was used to evaluate the separation accuracy of the improved ICA-R. Results show that the improved ICA-R algorithm could maintain the correlation coefficient of separation leakage at around 90% and the average relative error was within 15%
which was better than the FastICA algorithm. Instead of adding a large number of meters
the proposed method reduces the cost of calculation
and can provide reference for the calculation of leakage
so as to facilitate the water department to take targeted measures to control loss.