DUAN Liusheng, ZHANG Huabing, PAN Hong, et al. Experimental study on tensile properties of steel plate composite blind bolts as rebar mechanical connectors[J]. 2021, 53(10): 156-163.
DUAN Liusheng, ZHANG Huabing, PAN Hong, et al. Experimental study on tensile properties of steel plate composite blind bolts as rebar mechanical connectors[J]. 2021, 53(10): 156-163.DOI: 10.11918/202101132.
In order to achieve pull-through of transverse rebar of one-way precast slab to form two-way slab without wet operation or welding
considering the operability and efficiency of construction
steel plate composite blind bolts as rebar mechanical connectors were proposed. To study the tensile properties of the connectors
a monotonic tensile test was performed on 22 specimens. The research parameters were steel plate strength
number of bolts
pre-tightening force
and anchorage length
and the failure form
ultimate bearing capacity
load-displacement curve
and deformation capacity were investigated. Research results show that there were two failure modes of the specimens including fracture and pull-out of rebar. For the quenched and tempered 45# steel cover plate
the critical anchorage length of the reinforcing bar of the connector was between 2d and 3d. When it was less than the critical anchorage length
the rebar experienced scraping plough type pull-out; when it was larger than the critical anchorage length
the rebar would fracture. When the number of the connecting bolts was four
the specimens realized equal-strength connection of rebars. With the decrease in the width of the connecting cover
the critical anchorage length increased. Under the same anchorage length
the tensile strength of the joints increased with the increase in the pre-tightening force of the bolts. For the Q460C high-strength steel cover plate
the failure modes were deformation of the tooth nails and pull-out of the rebar. Under the same experimental conditions
the failure modes of the specimens with ribbed bars and rounded steel bars were the same. The formula for calculating the tensile bearing capacity of the proposed connector was proposed
and the analytical values agreed well with the experimental results
which could provide references for relevant design and research.