WANG Wei, WANG Bingjie, LUO Qirui, et al. Bond-slip behavior of interface between corrugated steel plate and concrete[J]. 2022, 54(4): 141-149.DOI: 10.11918/202109036.
To study the bond-slip behavior of interface between corrugated steel plate and concrete
ten corrugated steel plate-concrete specimens were designed for push-out test
considering concrete strength
concrete cover thickness
and embedded length of steel plate. The failure modes
stress mechanism
strain distribution
bond strength
and bond-slip constitutive relations of the specimens were studied. Test results show that bond splitting failure and bond anchorage failure mainly occurred in the corrugated steel plate-concrete composite members. The load-slip curve could be divided into micro-slip stage
slip stage
steep-drop stage
gentle-drop stage
and residual stage. At the load rising stage
the strain of the corrugated steel plate distributed exponentially along the embedded length
and the phenomenon of zero-point crossing of strain might occur at the free end of the steel plate. By analyzing the influences of concrete strength
concrete cover thickness
and embedded length of steel plate on the bond strength of interface between corrugated steel plate and concrete
the calculation formulas of characteristic bond strength were fitted linearly
and the error between theoretical values and test results was small. Based on the bond-slip constitutive model of interface between corrugated steel plate and concrete
typical specimens were simulated by using ABAQUS software
and the curves of finite element model were in good agreement with test results.