为提高钢-UHPC组合结构的延性
本文提出一种采用装配式栓钉连接的 钢-UHPC组合板。设计并完成了不同抗剪连接程度的组合板的抗弯性能试验
分析了组合板试件破坏形态、极限承载力、刚度、裂缝发展规律和板端滑移
并与采用焊接栓钉的钢-UHPC组合板进行了对比分析
讨论了组合板试件的可拆卸性
最后对其极限抗弯承载力和抗弯刚度进行了理论分析并推导了计算公式。结果表明:装配式栓钉连接的钢-UHPC组合板破坏模式为纵向水平剪切黏结破坏;降低栓钉间距能提高组合板的协同变形能力
从而提高组合板结构的极限承载力、弹塑性阶段的刚度和裂缝控制能力;与采用焊接栓钉连接的钢-UHPC组合板对比
其在发生较大变形的情况下钢板和UHPC板仍然可较容易地拆卸分离;推导了装配式栓钉连接的钢-UHPC组合板的极限承载力计算方法和抗弯刚度计算公式
提出了抗弯刚度计算时应对UHPC板高度进行折减
折减系数(βU)在正常使用阶段建议为0.85
理论计算结果与试验结果吻合良好。本文研究成果可为采用装配式栓钉的钢-UHPC组合板的设计和应用提供理论依据。
To improve the ductility of steelultra-high performance concrete (UHPC) composite structures
we proposed a type of demountable steelUHPC composite slab based on demountable shear connectors. The flexural tests for demountable steelUHPC composite slabs with different shear connection degrees were designed and completed. The failure mode
ultimate capacity
stiffness
cracking behavior
and relative slip of demountable steelUHPC composite slabs were analyzed and compared with those of steelUHPC composite slabs with welded shear connectors. The demountability of demountable steelUHPC composite slabs was discussed. The ultimate flexural capacity and flexural stiffness of demountable steelUHPC composite slabs were theoretically analyzed
and related calculation formulas were deduced. Results showed that the failure mode of demountable steelUHPC composite slabs was longitudinal horizontal shear bonding failure. Reducing the stud spacing could enhance the cooperative deformation capacity of demountable steelUHPC composite slabs
resulting in the improvement of their ultimate flexural capacity
stiffness at the elastic-plastic stage
and crack control ability. Different from the steelUHPC composite slabs with welded shear connectors
the steel slab and UHPC slab of the demountable steelUHPC composite slabs could be easily disassembled even in the condition of large deformation. The formulas for the ultimate flexural capacity and flexural stiffness of demountable steelUHPC composite slabs were derived. It was proposed that the height of UHPC slab should be reduced when calculating the flexural stiffness
and the reduction coefficient (βU) was suggested to be 0.85 in serviceability state. The theoretical calculation results were in good agreement with the test results. The research results can provide theoretical basis for the design and application of steelUHPC composite slabs with demountable shear connectors.