为研究超高性能混凝土(UHPC)免拆模板钢筋混凝土(URC)柱的抗震性能
选取UHPC免拆模板拼接方式和表面处理方式为试验设计参数
制作并完成了9个URC柱和1个钢筋混凝土(RC)柱的拟静力加载试验。模板拼接方式为螺栓加角钢连接、螺栓连接和环氧树脂砂浆连接;表面处理方式为光面处理、气泡膜印花处理和设肋处理
通过拟静力试验研究了模板拼接方式及表面处理方式对该类柱抗震性能的影响。此外
基于平截面假定
提出了URC柱的正截面偏压承载力计算式。结果表明:峰值荷载前
UHPC模板与核心混凝土黏结面无明显破坏
URC柱表现出良好的整体性
尤其是采用螺栓加角钢连接的URC柱
即使加载至极限位移时
也没有发生界面黏结失效破坏;与普通RC柱相比
URC柱的承载力提高了6.4%~43.3%
延性提高了11.4%~48.7%
耗能能力提高了27.7%~85.3%;三种连接方式中
采用螺栓加角钢连接的URC柱承载力最高
连接最可靠。最后
基于平截面假定提出的公式计算值与试验值吻合较好
可为工程应用提供参考。
To investigate the seismic behavior of reinforced concrete (RC) columns with stay-in-place ultra-high performance concrete (UHPC) formworks
named URC columns for short
we selected different assembly methods and surface treatment methods of UHPC formworks as design parameters and carried out pseudo-static tests on nine URC columns and one RC column. The assembly methods of UHPC formworks were boltangle steel connection
bolt connection
and epoxy resin mortar. The surface treatment methods of UHPC formworks were natural surface
bubble film printing
and adding ribs. The pseudo-static tests were conducted to study the influence of different assembly methods and surface treatment methods on the seismic behaviors of the URC columns. Additionally
on the basis of the assumption of plane section
a formula was proposed to predict the eccentric compressive bearing capacity of the URC columns. Results show that the bonding surface between UHPC formwork and concrete core had no apparent damage before the peak load
indicating that the URC columns have good integrity. In particular
the URC columns connected by boltangle steel had no interface bonding failure even under the failure load. Compared with the traditional RC column
the ultimate bearing capacity
ductility
and energy consumption of the URC columns were increased by 6.4%43.3%
11.4%48.7%
and 27.7%85.3%
respectively. Among the three assembly methods
the URC columns connected by bolt and angle steel had the highest bearing capacity and the most reliable connection. Finally
the results calculated by the proposed formula were in good agreement with the test results
which can provide reference for practical application.