1. 中国科学院声学研究所 国家网络新媒体工程技术研究中心,北京,100190
2. 中国科学院大学,北京,100039
孟祥辉(1990—),男,博士
纸质出版:2017
移动端阅览
孟祥辉, 曾学文, 陈晓, 等. FusionCache: 采用闪存的iSCSI存储端融合缓存机制[J]. 哈尔滨工业大学学报, 2017,49(11):2017-11.
MENG Xianghui, ZENG Xuewen, CHEN Xiao, et al. FusionCache: A Fusion Cache Mechanism for iSCSI Target Based on Flash Memory[J]. 2017, 49(11): 2017-11.
孟祥辉, 曾学文, 陈晓, 等. FusionCache: 采用闪存的iSCSI存储端融合缓存机制[J]. 哈尔滨工业大学学报, 2017,49(11):2017-11. DOI: 10.11918/j.issn.0367-6234.201701022.
MENG Xianghui, ZENG Xuewen, CHEN Xiao, et al. FusionCache: A Fusion Cache Mechanism for iSCSI Target Based on Flash Memory[J]. 2017, 49(11): 2017-11. DOI: 10.11918/j.issn.0367-6234.201701022.
针对原生的iSCSI目标端控制器缺乏独立的缓存模块问题,为了进一步提高存储区域网的整体性能,在iSCSI target软件中引入了一种基于闪存的融合缓存机制FusionCache. FusionCache利用闪存和DRAM组成统一的融合缓存架构,闪存充当DRAM的扩展空间,DRAM分为缓存块元数据区和前端缓存区.元数据区基于基数树管理缓存块元数据,用于加速缓存块的查找;前端缓存区基于回归拟合统计并预测缓存块访问热度,并吸收大量写入对闪存带来的冲击,只允许热点数据进入闪存. FusionCache采用改进的LRU算法对缓存块进行替换,并且在写回过程中考虑iSCSI会话状态.实验结果表明:FusionCache能降低对后端磁盘设备的访问频率,提高I/O响应的速度和吞吐.与只采用DRAM的缓存机制以及原生iSCSI target相比,FusionCache的I/O访问延时分别降低了33%和60%,吞吐分别提高了25%和54%;相较于Facebook提出的Flashcache机制,FusionCache的吞吐性能提高了18%,延时降低了27%;FusionCache还具有良好的读缓存命中率;此外,FusionCache能够减少闪存的写入次数,提高闪存使用寿命. FusionCache提供良好的网络存储效率,并且降低了使用成本.
Focusing on the problem of lack of independent cache module of original iSCSI target controller
we introduce a fusion cache mechanism based on flash memory called FusionCache into the iSCSI target software to further improve the overall performance of the storage area network. FusionCache uses flash memory and DRAM to form a unified fusion cache architecture. The flash memory acts as DRAM's expansion space
and DRAM is divided into cache block metadata area (metadata cache) and front-end buffer area (front cache). The metadata cache manages cache block metadata based on radix tree in order to accelerate the cache block searching; the front cache tallies and predicts the access popularity of the cache block based on regressing fitting model
and absorbs the impact of massive writes on flash memory to ensure that only the hot data is allowed to enter the flash memory. FusionCache uses the improved LRU algorithm to do cache replacement. Besides
it takes iSCSI session's state into account during write-back. The experimental results show that: FusionCache is able to reduce access to backend disk devices
and improve I/O response speed. FusionCache reduces I/O access latency by 33% and 60%
and improves throughput by 25% and 54%
compared to cache mechanism with only DRAM and original iSCSI target
respectively. Compared with Flashcache proposed by Facebook
FusionCache improves throughput by 18% and reduces latency by 27%. FusionCache also has a good read cache hit rate. Besides
FusionCache reduces write amount of flash memory
thus extends its life. FusionCache provides good efficiency of network storage and reduces cost.
0