ZHI Xudong, GONG Jun, FAN Feng. Research on the seismic fragility of orthogonal pyramid space grid[J]. 2017, 49(12): 2017-12.DOI: 10.11918/j.issn.0367-6234.201705079.
Seismic fragility analysis can accurately estimate seismic performance of a structure
to propose a method to study on the seismic fragility of space grid structure
the full-load field time-history analysis
parameter sensitivity analysis and seismic fragility analysis were carried out. The results show that space grid structure has a ductile damage with obvious signs. The responses of this kind of structure are more sensitive to steel yield strength
floor loads and ground motion records
which can be considered as random factors in subsequent analysis. The seismic damage index and damage grading standard
which are applicable to orthogonal pyramid space grid
were proposed based on the seismic response of whole process. According to the seismic fragility analysis
the probability of ensuring intactness at PGA=0.40g is 95%
while 79% at PGA=0.62g. The orthogonal pyramid space grid has a good seismic performance