In order to investigate the windage heating effect on rotating disc in cavity of rotor-stator system
an experimental research was performed using infrared temperature measurement technology. A high-speed revolution test rig was developed to investigate the effect of flow parameters and rotor-stator gap ratio on the temperature rise along the radius on rotating disc surface respectively. The shrouded and unshrouded cases were both tested. The flow feature in the cavity of rotor-stator system was obtained by CFD simulation. The results show that the temperature rise on the rotating disc induced by the windage heating is difference between adiabatic wall temperature of rotating disc and environment temperature
which can be measured by the thermal infrared imager accurately. For the unshrouded case
the temperature rise of rotating disc is mainly affected by the rotation
and only for the small gap ratio case
the throughflow has influence on the windage heating. In general
the gap ratio has limited influence on temperature rise. Comparison of the shrounded case
the temperature rise occurs only for the small turbulence parameter case with shrouded stationary.