Using two-dimensional compressible Euler equations
the flow field in continuously rotating detonation combustor (CRDC) with equivalent hydrogen/air was numerically analyzed. The effects of fuel inflow total pressure at different azimuthal sizes of CRDC on pressure ratio
combustion efficiency
volume heat release rate and NOx emissions were examined. The results show that with the increase of fuel inflow total pressure
when azimuthal size of CRDC is 150mm
pressure ratio remains unchanged
and combustion efficiency and volume heat release rate grow linearly; when azimuthal size of CRDC is 250mm
detonation wave number redoubles
and volume heat release rate still grow linearly
but pressure ratio and combustion efficiency turn down due to the increase of fuel inflow total pressure. Compared with conventional isobaric combustor
CRDC has a higher performance. In the calculation region of 250mm×40mm
the pressure ratio goes up to 2.706
greatly improving the potential power of gas; volume heat release rate is 2.18 ×1010W/m3; NOx emissions is 0.692mg/m3