On the basis of the baseline nozzle with annular mixer
the far field noise spectra performance and the noise reduction of the nozzle with lobed mixer were investigated under cold jet condition through scaled model experiments of high bybass ratio turbofan engine mixing exhaust system. The experiments were carried out on the jet noise experiment rig in the anechoic chamber. The experimental results show that
compared with the baseline nozzle with annular mixer
the nozzle with lobed mixer has better jet noise reduction at low frequencies
but the sound pressure level increases at high frequencies
while overall sound pressure level reduces at downstream(θ=150°)but increases at middlestream and upstream. With increased velocity differences between core exit flow and fan exit flow of lobed mixer
the nozzle with lobed mixer has better noise reduction at low frequencies
but the sound pressure level increases at high frequencies
while overall sound pressure level reduces at downstream(θ=150°)but increases at middlestream and upstream.