In order to understand the impact of asynchronous ignition phase on the knock of twostroke kerosene aeropiston engine
a calculation model of the combustion chamber was established by using fire software. And the validity of the model was verified by the test data. The simulation and test results show that: at 5000r/min
full load and equivalence ratio of the mixture under 11 conditions
ignition energy at 3564mJ conditions
when one of the spark plugs ignition time is fixed at before top dead center crank angle is 29°
another ignition time is set ahead of crank angle is 1°
3° and 5° relatively; with the increase of the phase difference of the double spark ignition
the average pressure
heat release rate and the accumulated heat release rate have decreased. The turbulent kinetic energy of the two spark plugs increases
the flame propagation velocity rises
the flame development period is shortened