The experimental system of constant volume combustion bomb for measuring laminar flame speed under the conditions of high temperature and pressure was designed and built. The composition and function of main subsystems
and the data processing method were introduced in detail. Moreover
at 400K temperature and 01
03MPa pressures the laminar flame speeds of C7 Fuels including toluene/methylcyclohexane/nheptane were measured
and compared with existing literature results. Results indicate that the experimental system has high reliability. Using this experimental system
laminar flame speeds can be accurately measured at high temperatures and elevated pressures
meanwhile the range of equivalence ratios can be extended.