To solve the thermal management problem of electronic equipments
according to the micro convex structure of the hydrophilic plant
three flat heat pipes: normal evaporator (No1)
superhydrophilic evaporator (No2)
the matched superhydrophilic evaporator and superhydrophobic condenser (No3) were constructed with conical capillary wicks
using electrolytic copper powder of the particle diameter 75μm as sintering material. Experiments were conducted to study the effect of heating power Q and tilt angle on the three flat heat pipes with deionized water as the working fluid. The results show that angle almost has no effect on the three flat heat pipes
namely
the three flat heat pipes all have good antigravity performance. The No3 flat heat pipe has the best thermal performance; when tilt angle of 0° and Q=1404W
the central point temperature of the evaporation is just 670℃. The No3 flat heat pipe has not only the smallest evaporation thermal resistance
but also the smallest condensation thermal resistance